LULA Elevators by Custom Elevator Manufacturing
Overview
T.L. Shield & Associates, Inc. distributes the Custom Elevator Manufacturing Limited Use Limited Application LULA Elevators. The founders of Custom Elevator Manufacturing, who introduced the first roped hydraulic commercial elevator to the U.S. market, are back to set the standards for LULA elevator systems. Their roped 1:2 hydraulic design provides the quietest and smoothest operation in the industry. This system utilizes components and devices that are tested and certified to the most stringent requirements and have been tried and proven on commercial mid- rise elevator applications subject to more frequent use. Their commitment to quality, safety, and dependability are unparalleled. Custom Elevator Manufacturing's unique design minimizes hoistway space, machine room space, pit depth, and overhead clearances and operates on stan- dard single phase power. This, combined with the flexibility to have the machine equipment located remotely and car sizes customized to fit most any conditions, makes our system ideal for remodeling projects or new construction buildings. At Custom Elevator Manufacturing Company and T.L. Shield & Associates, Inc., our main focus is on service beyond the sale, state of the art technology, superior quality, product reliability, safety, and our top priority is always the customer. |
![]() |
A limited use/limited application LULA elevator is a power passenger elevator in which the use and application is limited by size, capacity, speed, and rise. These low-rise elevator systems bridge the gap between conventional commercial elevators and other undesirable lifts used to provide solutions for architectural barriers. A LULA elevator from Custom Elevator Manufacturing Company is designed and manufactured in accordance with ASME A17.1 "Safety Code For Elevators and Escalators" and offers features to meet accessibility and fire protec- tion guidelines, making this elevator a perfect, cost-effective solution for most small public building applications including churches, schools, lodges, restaurants, nursing homes, and more. |
Standard Features
|
CHARACTERISTICS • 30 fpm nominal car speed • *Up to 4 stops• *Up to 25'-0" travel • Minimum pit depth of 3'-6" required (14" minimum with alternative means) • Minimum overhead clearance of 11'-0" required (9'-6" minimum with alternative means for existing buildings) • 42" wide x 60" deep x 81" high nominal inside car size • 36" wide x 80" high fully automatic two-speed horizontal sliding doors *Consult factory for other custom options.
|
EQUIPMENT |
SAFETY DEVICES • Type "A" instantaneous governor actuated car safety • Pipe rupture valve • Upper and lower terminal limit switches • Top final limit switch • Slack cable switch • Emergency car lighting in cab • Emergency keyed stop switch in cab • Emergency push button alarm in cab • Automatic car releveling devic • Floor selectable battery lowering device • Emergency manual lowering valve • Emergency telephone in cab • Solid panel cab doors with approved safety switch • Infrared door edge protection with automatic door reopen system • Approved electro-mechanical hoistway door interlocks • Impact buffers below elevator car • UL and/or CSA certified electrical and hydraulic devices • Manufactured in accordance with ASME A17.1 Safety Code • Pit stop switch |
![]() |
CONTROL/PUSHBUTTON FIXTURES • Automatic pushbutton control • Microprocessor based control system with uninterrupted battery back-up emergency lowering with automatic door operation • Light-up push buttons in car and hall with Braille • Digital floor position indicator with direction arrows in car • Floor "Stop/Pass" audible signal in car • Automatic cab lighting with override switch • Automatic indicator light time-out feature • Automatic "Home Park" feature to designated floor • Low oil protection timer circuit • Top of car inspection operation • Recessed telephone box with phone |
![]() |
CAB FINISHES AND ACCESSORIES • Fire rated wood core wall panels with black filled reveals to simulate applied panels faced with plastic laminate available in several solid, textured, and wood grain finishes • Car entrance including strike column, return panel, and transom are #4 brushed stainless steel finish • Two speed reinforced hollow metal horizontal sliding car doors with #4 brushed stainless steel finish • Steel canopy with fire rated thermoclear panel suspended ceiling and fluorescent lighting above • 3/8" x 2" #4 brushed stainless steel handrail on (1) side wall • Extruded aluminum car sill • #4 brushed stainless steel certificate frame • Unfinished plywood sub-floor in cab HOISTWAY DOORS • Two speed horizontal sliding fire rated door and frame assemblies with prime (paintable) finish and extruded aluminum sills |
![]() |
LULA Options
Downloads
| The downloadable drawings in this section are provided by Custom Elevator Manufacturing. | ||||||||||||||||||||||||||||||||||||||||
|
|
|||||||||||||||||||||||||||||||||||||||
| **Drawings in AutoCAD format are offered as an added convenience to architects, builders and designers. Do not under any circumstances modify the dimensions within these drawings without consulting the factory. These drawings, and the Custom Elevator logo are copyrighted by Custom Elevator Manufacturing Company Incorporated. | ||||||||||||||||||||||||||||||||||||||||